{"id":265,"date":"2026-11-03T08:45:14","date_gmt":"2026-11-03T08:45:14","guid":{"rendered":"https:\/\/xlaqua.com\/products\/packaged-domestic-sewage-treatment\/"},"modified":"2026-11-03T08:45:14","modified_gmt":"2026-11-03T08:45:14","slug":"packaged-domestic-sewage-treatment","status":"publish","type":"page","link":"https:\/\/xlaqua.com\/zh\/products\/packaged-domestic-sewage-treatment\/","title":{"rendered":"XLDS Packaged Sewage Treatment"},"content":{"rendered":"<div class=\"top\"><div class=\"wrap\"><span>WASTEWATER EQUIPMENT \/ GUANGZHOU, CHINA<\/span><a href=\"tel:+8613610057417\">+86 136 1005 7417 \u2197<\/a><\/div><\/div>\r\n<header class=\"wrap\"><a class=\"brand\" href=\"https:\/\/xlaqua.com\/zh\/\"><b>XL<span>\u2197<\/span><\/b><strong>XIANG LV<small>HUANBAO \/ ENVIRONMENTAL EQUIPMENT<\/small><\/strong><\/a><button class=\"menu\" aria-expanded=\"false\" aria-controls=\"mainnav\">Menu \u2630<\/button><nav id=\"mainnav\" aria-label=\"Main navigation\"><a href=\"https:\/\/xlaqua.com\/zh\/\">\u9996\u9875<\/a><a href=\"#company\">\u5173\u4e8e\u6211\u4eec<\/a><a class=\"current\" href=\"#overview\">\u4ea7\u54c1\u8bbe\u5907<\/a><a href=\"#applications\">\u884c\u4e1a\u5e94\u7528<\/a><a href=\"https:\/\/xlaqua.com\/zh\/projects\/\">\u9879\u76ee\u6848\u4f8b<\/a><a href=\"#support\">\u5de5\u7a0b\u4e0e\u652f\u6301<\/a><a href=\"#resources\">\u6280\u672f\u8d44\u6599<\/a><a href=\"#contact\">\u8054\u7cfb\u6211\u4eec \u2197<\/a><\/nav><\/header>\r\n<main>\r\n<div class=\"wrap breadcrumb\">\u4ea7\u54c1\u8bbe\u5907 <span>\/<\/span> Domestic Sewage <span>\/<\/span> <b>XLDS Series<\/b><\/div>\r\n<section class=\"hero wrap\" id=\"overview\"><div class=\"hero-copy\"><p class=\"eyebrow\"><span class=\"dot\"><\/span> XLDS SERIES \/ PACKAGED TREATMENT<\/p><h1>Domestic sewage.<br>A defined<br><em>treatment system.<\/em><\/h1><p class=\"lead\">Packaged sewage treatment equipment for communities, schools and living quarters. Configured around your influent, site and treatment target.<\/p><div class=\"tags\"><span>A\u00b2\/O + MBR + UV*<\/span><span>Project-specific configuration<\/span><\/div><div class=\"buttons\"><a class=\"button\" href=\"#contact\">Discuss your project <span>\u2197<\/span><\/a><a class=\"plain\" href=\"https:\/\/xlaqua.com\/wp-content\/uploads\/2026\/11\/XL-P01_DWG_pfd_01.pdf\" target=\"_blank\" rel=\"noopener\">Process diagram \u2193<\/a><\/div><p class=\"fine\">*Listed XLDS configuration. Final process and performance conditions are confirmed for each project.<\/p><\/div><figure class=\"hero-picture\"><img decoding=\"async\" src=\"https:\/\/xlaqua.com\/wp-content\/uploads\/2026\/11\/XL-P01_EXT_front_01.webp\" alt=\"Front view of Xianglv packaged sewage equipment photographed in the workshop\"><span class=\"photo-label\">01 \/ ACTUAL EQUIPMENT PHOTOGRAPH<\/span><figcaption><span>XLDS \/ PACKAGED DOMESTIC SEWAGE SYSTEM<\/span><b>ENGINEERED TO THE PROJECT \u2197<\/b><\/figcaption><\/figure><\/section>\r\n<div class=\"wrap facts\"><div><small>REFERENCE MODELS<\/small><strong>10 \/ 20 \/ 30 <i>m\u00b3\/d<\/i><\/strong><\/div><div><small>TREATMENT ROUTE<\/small><strong>A\u00b2\/O \u2192 MBR \u2192 UV<\/strong><\/div><div><small>CONTROL OPTIONS<\/small><strong>PLC + Touchscreen<\/strong><\/div><div><small>DELIVERY APPROACH<\/small><strong>Equipment + Support<\/strong><\/div><\/div>\r\n<div class=\"anchor-bar\"><nav class=\"wrap\" aria-label=\"Product sections\"><a href=\"#applications\">01 Applications<\/a><a href=\"#process\">02 Process<\/a><a href=\"#models\">03 Technical data<\/a><a href=\"#configuration\">04 Configuration<\/a><a href=\"#support\">05 Delivery &amp; Support<\/a><a href=\"#faq\">06 FAQ<\/a><\/nav><\/div>\r\n<section class=\"section wrap\" id=\"applications\"><div class=\"section-head\"><div><p class=\"eyebrow\">01 \/ WHERE IT FITS<\/p><h2>For the places<br>people live and work.<\/h2><\/div><p>Start with actual sewage flow, water analysis and operating conditions. Occupancy alone does not determine the equipment model.<\/p><\/div><div class=\"applications\"><article><span>01 \u2197<\/span><h3>Communities<\/h3><p>Residential compounds and decentralized domestic sewage collection.<\/p><\/article><article><span>02 \u2197<\/span><h3>Schools &amp; campuses<\/h3><p>Review daily schedules, peak discharge and changing occupancy.<\/p><\/article><article><span>03 \u2197<\/span><h3>Living quarters<\/h3><p>Staff accommodation and camps with defined site and operating responsibilities.<\/p><\/article><\/div><\/section>\r\n<section class=\"dark section\" id=\"process\"><div class=\"wrap\"><div class=\"section-head\"><div><p class=\"eyebrow\">02 \/ TREATMENT PRINCIPLE<\/p><h2>One system.<br>Clearly defined stages.<\/h2><\/div><a class=\"plain\" href=\"https:\/\/xlaqua.com\/wp-content\/uploads\/2026\/11\/XL-P01_DWG_pfd_01.pdf\" target=\"_blank\" rel=\"noopener\">View the source process PDF \u2197<\/a><\/div><div class=\"flow\"><article><small>01 \/ BIOLOGICAL<\/small><h3>Anaerobic<\/h3><p>First zone in the listed A\u00b2\/O treatment arrangement.<\/p><\/article><article><small>02 \/ BIOLOGICAL<\/small><h3>Anoxic<\/h3><p>Project-specific biological process conditions.<\/p><\/article><article><small>03 \/ BIOLOGICAL<\/small><h3>Aerobic<\/h3><p>Aeration within the agreed treatment configuration.<\/p><\/article><article><small>04 \/ SEPARATION<\/small><h3>MBR<\/h3><p>Membrane separation in the listed XLDS process.<\/p><\/article><article><small>05 \/ DISINFECTION<\/small><h3>UV<\/h3><p>Disinfection stage selected for the project duty.<\/p><\/article><\/div><p class=\"fine\">Typical process flow \u2014 indicative only. Pretreatment, recirculation, sludge handling and detailed interfaces are defined in project engineering.<\/p><\/div><\/section>\r\n<section class=\"section wrap\" id=\"models\"><div class=\"section-head\"><div><p class=\"eyebrow\">03 \/ MODEL REFERENCE<\/p><h2>Compare the essentials.<\/h2><\/div><span class=\"badge\">REFERENCE DATA \/ SUBJECT TO TECHNICAL REVIEW<\/span><\/div><div class=\"model-switch\" role=\"group\" aria-label=\"Highlight a model\"><button class=\"active\" data-model=\"all\">All models<\/button><button data-model=\"XLDS-10\">XLDS-10<\/button><button data-model=\"XLDS-20\">XLDS-20<\/button><button data-model=\"XLDS-30\">XLDS-30<\/button><\/div><div class=\"table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"Model reference specifications\"><table><caption>XLDS series \u2014 reference specifications from the supplied parameter register<\/caption><thead><tr><th>Model<\/th><th>Design flow<br><small>m\u00b3\/d<\/small><\/th><th>L \u00d7 W \u00d7 H<br><small>mm<\/small><\/th><th>Installed power<br><small>kW<\/small><\/th><th>Empty \/ operating<br><small>t<\/small><\/th><th>Shipping reference<\/th><\/tr><\/thead><tbody><tr data-row=\"XLDS-10\"><th>XLDS-10<\/th><td>10<\/td><td>3,600 \u00d7 1,500 \u00d7 2,600<\/td><td>3.5<\/td><td>2.2 \/ 10<\/td><td>Complete unit<\/td><\/tr><tr data-row=\"XLDS-20\"><th>XLDS-20<\/th><td>20<\/td><td>5,000 \u00d7 2,000 \u00d7 2,600<\/td><td>5.5<\/td><td>3.2 \/ 19<\/td><td>Complete unit<\/td><\/tr><tr data-row=\"XLDS-30\"><th>XLDS-30<\/th><td>30<\/td><td>5,200 \u00d7 2,500 \u00d7 3,000<\/td><td>7.5<\/td><td>4.5 \/ 28<\/td><td>In sections<\/td><\/tr><\/tbody><\/table><\/div><p class=\"fine note\">Source: supplied model register, 2026-11-02. Technical sign-off remains pending. Installed power is not actual energy consumption. Dimensions and weights are not a packing, lifting or foundation design guarantee.<\/p><\/section>\r\n<section class=\"soft section\" id=\"configuration\"><div class=\"wrap configuration\"><div><p class=\"eyebrow\">04 \/ EQUIPMENT DETAILS<\/p><h2>Look beyond<br>the outer shell.<\/h2><figure class=\"detail-photo\"><img decoding=\"async\" src=\"https:\/\/xlaqua.com\/wp-content\/uploads\/2026\/11\/XL-P01_DET_rotaryblower_01.webp\" alt=\"Rotary blower detail from Xianglv equipment documentation\" loading=\"lazy\"><figcaption>ACTUAL COMPONENT PHOTOGRAPH \/ ROTARY BLOWER<\/figcaption><\/figure><\/div><div class=\"specs\"><article><small>01<\/small><div><h3>Materials selected for the duty<\/h3><p>Coated carbon steel, stainless steel 304 \/ 316 or FRP can be considered. Actual series construction and corrosion protection are confirmed per project.<\/p><\/div><\/article><article><small>02<\/small><div><h3>Controls that fit your operation<\/h3><p>PLC and touchscreen control can be provided. English HMI, remote monitoring and mobile alerts are optional configurations.<\/p><\/div><\/article><article><small>03<\/small><div><h3>Defined equipment scope<\/h3><p>The register lists the main treatment unit, blower, pumps and mixer. Final equipment, quantities, interfaces and exclusions belong in the technical proposal.<\/p><\/div><\/article><article><small>04<\/small><div><h3>Installation matched to the site<\/h3><p>Above-ground or buried arrangements can be considered. Groundwater, soil, structural loads, access and maintenance conditions require review.<\/p><\/div><\/article><\/div><\/div><\/section>\r\n<section class=\"section wrap basis\"><div><p class=\"eyebrow\">DESIGN BASIS \/ BEFORE SELECTION<\/p><h2>Know the water.<br>Agree the target.<\/h2><p>The listed XLDS inlet reference applies to the registered series configuration. It is not an effluent guarantee or a universal treatment envelope.<\/p><a class=\"text-link\" href=\"#contact\">Prepare your design information \u2197<\/a><\/div><dl><div><dt>CODcr<\/dt><dd>\u2264 400 mg\/L<\/dd><\/div><div><dt>BOD\u2085<\/dt><dd>\u2264 150 mg\/L<\/dd><\/div><div><dt>Suspended solids<\/dt><dd>\u2264 150 mg\/L<\/dd><\/div><div><dt>Ammonia nitrogen<\/dt><dd>\u2264 30 mg\/L<\/dd><\/div><div><dt>Total nitrogen \/ phosphorus<\/dt><dd>\u2264 40 \/ \u2264 4 mg\/L<\/dd><\/div><div><dt>pH<\/dt><dd>6.5\u20138.5<\/dd><\/div><\/dl><\/section>\r\n<section class=\"soft section\" id=\"support\"><div class=\"wrap\"><div class=\"section-head\"><div><p class=\"eyebrow\">05 \/ ENGINEERING &amp; DELIVERY<\/p><h2>From design inputs<br>to site readiness.<\/h2><\/div><p>Equipment, documents and support form an agreed scope. Local works, services and costs are clarified before the order.<\/p><\/div><div class=\"workflow\"><article><b>01<\/b><h3>Define the duty<\/h3><p>Sewage source, average and peak flow, daily hours, water analysis and discharge or reuse target.<\/p><\/article><article><b>02<\/b><h3>Confirm the package<\/h3><p>Process, construction, controls, equipment list, interfaces and English documentation.<\/p><\/article><article><b>03<\/b><h3>Agree inspection<\/h3><p>On-site, video or third-party inspection. Test items and acceptance criteria by agreement.<\/p><\/article><article><b>04<\/b><h3>Prepare the site<\/h3><p>Foundations, lifting, utilities and local installation. Remote or on-site support as agreed.<\/p><\/article><\/div><\/div><\/section>\r\n<section class=\"section wrap project\" id=\"project\"><div><p class=\"eyebrow\">PROJECT REFERENCE \/ ANONYMOUS<\/p><h2>A domestic sewage<br>equipment reference.<\/h2><p>The company register records a <strong>50 m\u00b3\/d domestic sewage project with an A\u00b2\/O configuration<\/strong>. This is a project-specific reference, separate from the current XLDS-10 \/ 20 \/ 30 model table.<\/p><p class=\"fine\">Registered outlet values are contract design limits, not measured operating results. Site photography is omitted pending permission.<\/p><\/div><div class=\"project-number\"><span>RECORDED DESIGN FLOW<\/span><strong>50<small>m\u00b3\/d<\/small><\/strong><span>ANONYMOUS REFERENCE \/ C04<\/span><\/div><\/section>\r\n<section class=\"section soft\" id=\"faq\"><div class=\"wrap faq-layout\"><div><p class=\"eyebrow\">06 \/ QUESTIONS BEFORE PURCHASE<\/p><h2>A clearer starting point.<\/h2><a class=\"text-link\" id=\"resources\" href=\"https:\/\/xlaqua.com\/wp-content\/uploads\/2026\/11\/XL-P01_DWG_pfd_01.pdf\" target=\"_blank\" rel=\"noopener\">Download typical process diagram \u2193<\/a><\/div><div><details><summary>What do you need to select a model?<\/summary><p>Average and peak flow with units, sewage source, representative analysis, target limits, daily operating hours, location, site conditions and available utilities.<\/p><\/details><details><summary>Is A\u00b2\/O + MBR + UV always the right process?<\/summary><p>No. It is the listed XLDS reference configuration. Actual process selection depends on the influent, required treatment target and operating conditions.<\/p><\/details><details><summary>Can you provide installation and commissioning support?<\/summary><p>Remote guidance, on-site installation and commissioning support, and training can be provided. Scope, scheduling, local responsibilities, travel and costs are agreed for each project.<\/p><\/details><details><summary>Which English documents can be provided?<\/summary><p>English operation manuals, electrical drawings and process flow diagrams can be provided within the agreed scope. The typical product process PDF is available on this page.<\/p><\/details><\/div><\/div><\/section>\r\n<section class=\"contact section\" id=\"contact\"><div class=\"wrap\"><p class=\"eyebrow\">START WITH YOUR PROJECT<\/p><h2>Tell us about the sewage.<br>Let\u2019s define the equipment.<\/h2><p>Prepare the wastewater source, average and peak flow, treatment target and site location. We can start with the information available.<\/p><div class=\"buttons\"><a class=\"button\" href=\"tel:+8613610057417\">Call +86 136 1005 7417 \u2197<\/a><button class=\"outline\" id=\"download-brief\">Download enquiry checklist \u2193<\/button><\/div><p class=\"fine\">Project scope, technical specifications and service arrangements are confirmed individually.<\/p><\/div><\/section>\r\n<\/main><footer class=\"wrap\" id=\"company\"><div><strong>XIANG LV HUANBAO<\/strong><p>Guangzhou Xiang Lv Environmental Protection Equipment Co.,ltd.<br>Established in 2014 \u00b7 Wastewater treatment equipment<\/p><\/div><span>XLDS PRODUCT PAGE \/ DESIGN PREVIEW<br>\u00a9 2026 XIANG LV HUANBAO<\/span><\/footer>","protected":false},"excerpt":{"rendered":"<p>WASTEWATER EQUIPMENT \/ GUANGZHOU, CHINA+86 136 1005 7417 \u2197 XL\u2197XIANG LVHUANBAO \/ ENVIRONMENTAL EQUIPMENTMenu \u2630 HomeAbout UsProductsApplicationsProjectsEngineering &amp; SupportResourcesContact \u2197 Products \/ Domestic Sewage \/ XLDS Series XLDS SERIES \/ PACKAGED TREATMENT Domestic sewage.A definedtreatment system. Packaged sewage treatment equipment for communities, schools and living quarters. Configured around your influent, site and treatment target. A\u00b2\/O [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":258,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-265","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/pages\/265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/comments?post=265"}],"version-history":[{"count":0,"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/pages\/265\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/pages\/258"}],"wp:attachment":[{"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/media?parent=265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}