{"id":267,"date":"2026-11-03T08:45:15","date_gmt":"2026-11-03T08:45:15","guid":{"rendered":"https:\/\/xlaqua.com\/projects\/domestic-sewage\/"},"modified":"2026-11-03T08:45:15","modified_gmt":"2026-11-03T08:45:15","slug":"domestic-sewage","status":"publish","type":"page","link":"https:\/\/xlaqua.com\/zh\/projects\/domestic-sewage\/","title":{"rendered":"Domestic sewage"},"content":{"rendered":"<div class=\"top\"><div class=\"wrap\"><span>WASTEWATER EQUIPMENT \/ GUANGZHOU, CHINA<\/span><a href=\"tel:+8613610057417\">+86 136 1005 7417 \u2197<\/a><\/div><\/div>\r\n<header class=\"wrap\"><a class=\"brand\" href=\"https:\/\/xlaqua.com\/zh\/\"><b>XL<span>\u2197<\/span><\/b><strong>XIANG LV<small>HUANBAO \/ ENVIRONMENTAL EQUIPMENT<\/small><\/strong><\/a><button class=\"menu\" aria-expanded=\"false\" aria-controls=\"mainnav\">Menu \u2630<\/button><nav id=\"mainnav\" aria-label=\"Main navigation\"><a href=\"https:\/\/xlaqua.com\/zh\/\">\u9996\u9875<\/a><a href=\"https:\/\/xlaqua.com\/zh\/about\/\">\u5173\u4e8e\u6211\u4eec<\/a><a href=\"https:\/\/xlaqua.com\/zh\/#products\">\u4ea7\u54c1\u8bbe\u5907<\/a><a href=\"https:\/\/xlaqua.com\/zh\/#applications\">\u884c\u4e1a\u5e94\u7528<\/a><a href=\"https:\/\/xlaqua.com\/zh\/projects\/\" class=\"current\" aria-current=\"page\">\u9879\u76ee\u6848\u4f8b<\/a><a href=\"https:\/\/xlaqua.com\/zh\/#support\">\u5de5\u7a0b\u4e0e\u652f\u6301<\/a><a href=\"https:\/\/xlaqua.com\/zh\/#resources\">\u6280\u672f\u8d44\u6599<\/a><a href=\"https:\/\/xlaqua.com\/zh\/#contact\">\u8054\u7cfb\u6211\u4eec \u2197<\/a><\/nav><\/header>\r\n\r\n<main><div class=\"wrap breadcrumb\"><a href=\"https:\/\/xlaqua.com\/zh\/\">\u9996\u9875<\/a> <span>\/<\/span> <a href=\"https:\/\/xlaqua.com\/zh\/projects\/\">\u9879\u76ee\u6848\u4f8b<\/a> <span>\/<\/span> C04<\/div><section class=\"section wrap detail-hero\"><div><p class=\"eyebrow\">C04 \/ ANONYMOUS PROJECT REFERENCE<\/p><h1>Domestic sewage<\/h1><p class=\"lead\">A registered domestic sewage project with an A\u00b2\/O configuration.<\/p><div class=\"tags\"><span>Recorded equipment project<\/span><span>Recorded project-specific route<\/span><\/div><\/div><div class=\"detail-flow\"><span>RECORDED DESIGN FLOW<\/span><strong>50<small>m\u00b3\/d<\/small><\/strong><p>Design duty, not measured operating throughput<\/p><\/div><\/section><div class=\"dark section\"><div class=\"wrap\"><p class=\"eyebrow\">RECORDED PROCESS STAGES<\/p><h2>A route defined for this project.<\/h2><div class=\"record-route\"><span><small>01<\/small>Anaerobic zone<\/span><span><small>02<\/small>Anoxic zone<\/span><span><small>03<\/small>Aerobic zone<\/span><\/div><p class=\"fine\">Text schematic of registered stages. It is not a complete project PFD, a fixed equipment specification or an as-built drawing.<\/p><\/div><\/div><section class=\"section wrap detail-context\"><div><p class=\"eyebrow\">01 \/ WASTEWATER &amp; PROJECT CONTEXT<\/p><h2>Start with the duty.<\/h2><\/div><div><p>The company register records a domestic sewage equipment project with a design flow of 50 m\u00b3\/d. Detailed influent values and the public location are not supplied in the approved summary.<\/p><h3>What the public record supports<\/h3><p>A\u00b2\/O is the registered biological process for this project. Additional equipment and civil, installation or operating responsibilities require the specific project documents.<\/p><\/div><\/section><section class=\"section soft\"><div class=\"wrap\"><div class=\"section-head\"><div><p class=\"eyebrow\">02 \/ DESIGN INFORMATION<\/p><h2>Separate the inlet<br>from the target.<\/h2><\/div><p>Company water-quality register, dated 2026-10-30. Values below are registered design information, not a before-and-after test.<\/p><\/div><div class=\"design-tables\"><article><span class=\"data-label\">REGISTERED INLET \/ DESIGN BASIS<\/span><div class=\"no-data\"><h3>Detailed inlet values not provided.<\/h3><p>A representative water analysis is needed when reviewing a new sewage duty.<\/p><\/div><\/article><article><span class=\"data-label\">CONTRACT DESIGN TARGETS \/ NOT MEASURED<\/span><div class=\"table-wrap\"><table><caption>Registered contractual outlet limits<\/caption><thead><tr><th>Parameter<\/th><th>Recorded value<\/th><\/tr><\/thead><tbody><tr><th>pH<\/th><td>6\u20139<\/td><\/tr><tr><th>COD<\/th><td>\u2264 70 mg\/L<\/td><\/tr><tr><th>Suspended solids<\/th><td>\u2264 30 mg\/L<\/td><\/tr><tr><th>Ammonia nitrogen<\/th><td>\u2264 15 mg\/L<\/td><\/tr><tr><th>Animal \/ vegetable oil<\/th><td>\u2264 5 mg\/L<\/td><\/tr><\/tbody><\/table><\/div><\/article><\/div><p class=\"fine note\">The register states that total phosphorus and total nitrogen are not assessed in the listed contract targets. This 50 m\u00b3\/d project is separate from the current XLDS-10 \/ 20 \/ 30 model directory.<\/p><\/div><\/section><section class=\"section wrap evidence-layout\"><div><p class=\"eyebrow\">03 \/ PERFORMANCE EVIDENCE<\/p><h2>Design limits<br>are not test results.<\/h2><\/div><div><p>The public reference does not include a measured outlet dataset or independently verified removal rate. No operating acceptance status is claimed on this page.<\/p><p>For a new project, influent conditions, discharge or reuse limits, sampling methods and acceptance criteria must be agreed separately.<\/p><\/div><\/section><section class=\"soft section\"><div class=\"wrap\"><div class=\"section-head\"><div><p class=\"eyebrow\">04 \/ CONTINUE THE EQUIPMENT DISCUSSION<\/p><h2>Explore related equipment.<\/h2><\/div><\/div><div class=\"related-equipment\"><a href=\"https:\/\/xlaqua.com\/zh\/products\/packaged-domestic-sewage-treatment\/\"><span>Packaged sewage equipment<\/span><b>\u2197<\/b><\/a><\/div><p class=\"fine\">Related equipment describes a discussion entry, not confirmation of the exact model installed in this project.<\/p><a class=\"text-link\" href=\"https:\/\/xlaqua.com\/zh\/projects\/\">\u2190 All project references<\/a><\/div><\/section><section class=\"contact section\" id=\"contact\"><div class=\"wrap contact-layout\"><div><p class=\"eyebrow\">DISCUSS A SIMILAR DUTY<\/p><h2>Your wastewater.<br>Its own design basis.<\/h2><p>Share the source, average and peak flow, water analysis and treatment target. We can discuss the equipment and information needed for your project.<\/p><\/div><div class=\"contact-actions\"><a class=\"button\" href=\"https:\/\/xlaqua.com\/zh\/applications\/industrial\/#inputs\">Prepare your project brief \u2197<\/a><a class=\"plain\" href=\"tel:+8613610057417\">Call +86 136 1005 7417 \u2197<\/a><\/div><\/div><\/section><\/main><footer class=\"wrap\"><div><a href=\"https:\/\/xlaqua.com\/zh\/\" class=\"footer-brand\">XIANG LV HUANBAO<\/a><p>Guangzhou Xiang Lv Environmental Protection Equipment Co.,ltd.<br>Established in 2014 \u00b7 Guangzhou, China<\/p><\/div><div class=\"footer-links\"><a href=\"https:\/\/xlaqua.com\/zh\/\">\u9996\u9875<\/a><a href=\"https:\/\/xlaqua.com\/zh\/about\/\">\u5173\u4e8e\u6211\u4eec<\/a><a href=\"https:\/\/xlaqua.com\/zh\/projects\/\">\u9879\u76ee\u6848\u4f8b<\/a><\/div><span>\u00a9 2026 XIANG LV HUANBAO<br>Equipment \u00b7 Documents \u00b7 Project support<\/span><\/footer>","protected":false},"excerpt":{"rendered":"<p>WASTEWATER EQUIPMENT \/ GUANGZHOU, CHINA+86 136 1005 7417 \u2197 XL\u2197XIANG LVHUANBAO \/ ENVIRONMENTAL EQUIPMENTMenu \u2630 HomeAbout UsProductsApplicationsProjectsEngineering &amp; SupportResourcesContact \u2197 Home \/ Projects \/ C04 C04 \/ ANONYMOUS PROJECT REFERENCE Domestic sewage A registered domestic sewage project with an A\u00b2\/O configuration. Recorded equipment projectRecorded project-specific route RECORDED DESIGN FLOW50m\u00b3\/d Design duty, not measured operating throughput [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":259,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-267","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/pages\/267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/comments?post=267"}],"version-history":[{"count":0,"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/pages\/267\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/pages\/259"}],"wp:attachment":[{"href":"https:\/\/xlaqua.com\/zh\/wp-json\/wp\/v2\/media?parent=267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}