| Parameter | Recorded value |
|---|---|
| pH | 2 |
| COD | 25,000 mg/L |
| Total phosphorus | 800 mg/L |
C03 / ANONYMOUS PROJECT REFERENCE
Biopharmaceutical wastewater
A project-specific route combining pretreatment, UASB and biological treatment.
Design duty, not measured operating throughput
RECORDED PROCESS STAGES
A route defined for this project.
Text schematic of registered stages. It is not a complete project PFD, a fixed equipment specification or an as-built drawing.
01 / WASTEWATER & PROJECT CONTEXT
Start with the duty.
The company register records biopharmaceutical wastewater with the listed high-concentration design inputs. The record is specific to this wastewater and must not be used as the general XLWW inlet envelope.
What the public record supports
The available public summary records the treatment train and equipment project reference. Detailed contractual responsibilities, unit specifications and acceptance stage are not established by this public summary.
02 / DESIGN INFORMATION
Separate the inlet
from the target.
Company water-quality register, dated 2026-10-30. Values below are registered design information, not a before-and-after test.
| Parameter | Recorded value |
|---|---|
| pH | 6–9 |
| COD | ≤ 500 mg/L |
| Ammonia nitrogen | ≤ 45 mg/L |
| Total nitrogen | ≤ 70 mg/L |
| Total phosphorus | ≤ 8 mg/L |
This route is project-specific. It is not a standard configuration or performance guarantee for every pharmaceutical stream or XLWW model.
03 / PERFORMANCE EVIDENCE
Design limits
are not test results.
The public reference does not include a measured outlet dataset or independently verified removal rate. No operating acceptance status is claimed on this page.
For a new project, influent conditions, discharge or reuse limits, sampling methods and acceptance criteria must be agreed separately.
04 / CONTINUE THE EQUIPMENT DISCUSSION
Explore related equipment.
Related equipment describes a discussion entry, not confirmation of the exact model installed in this project.
← All project referencesDISCUSS A SIMILAR DUTY
Your wastewater.
Its own design basis.
Share the source, average and peak flow, water analysis and treatment target. We can discuss the equipment and information needed for your project.